Datasheet refresh
- One datasheet, up to 4 pages
- Test conditions stated; typical values kept apart from limits
- Curves redrawn from your data, in code
- A part-number key, and a list of gaps for your engineers
- One review round
I rewrite your datasheets and product pages from your measured data, with test conditions, specification limits and curves drawn from code.
NB-series Bandpass Filters
Rev AHigh performance bandpass filters for a wide range of applications.
| Wavelength | 532 nm |
|---|---|
| Bandwidth | 3 nm |
| Transmission | >85% |
| Blocking | OD5 |
| Size | 25 mm |
Specifications subject to change without notice.
NB-series narrow bandpass filter, 532 nm
Hard-coated bandpass for 532 nm laser line cleanup, 25.0 mm mounted
| Parameter | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Center wavelength | AOI 0°, 23 °C | 531.0 | 532.0 | 533.0 | nm |
| Bandwidth, FWHM | AOI 0° | 2.6 | 3.0 | 3.4 | nm |
| Peak transmission | at center, AOI 0° | 85 | 90 | % | |
| Blocking | 400 to 1100 nm, outside ±10 nm | 5.0 | 6.0 | OD | |
| Shift with angle | AOI 10°, n* 2.0 | −2.01 | nm | ||
| Clear aperture | 21.0 | mm | |||
| Diameter | 24.9 | 25.0 | 25.1 | mm |
All values at 23 °C with a collimated, unpolarized beam unless stated.
Center wavelength against angle of incidence for effective index 1.45 to 2.00. Tilt shifts the band to shorter wavelengths.
jezdangomez.com
The datasheet states test conditions, separates typical values from minimum and maximum limits, and includes curves, a drawing and a part-number key.
The product page answers technical questions before a request for quote.
The selection guide explains which parts meet the buyer’s requirements.
Line chart. Angle of incidence (°) from 0 to 60. n_eff 1.45: 1.000 to 0.802; n_eff 1.85: 1.000 to 0.884; n_eff 2.00: 1.000 to 0.901 (Center wavelength ratio λθ / λ0).
Missing the outline drawing? 3D models, drawings and CAD libraries are built from your released drawings.
Pick a stack, tilt it, and watch the reflectance curve and the color of the coating move. Every point is a transfer-matrix calculation running in your browser, the same method behind the curves on a filter datasheet.
Indices at λ₀ = 532 nm. Layers are drawn to scale with each other; the substrate is cut short.
Reflectance 3.51 percent and transmittance 96.5 percent at 532 nm, 0 degrees, average of s and p. Narrow bandpass at 532 nm, 15 layers on fused silica.
Reflected color
Y 97.1 %
x 0.324 y 0.347
Transmitted color
Y 2.91 %
x 0.184 y 0.122
Seen in D65 daylight by the CIE 1931 2° observer, shown in sRGB. Dim colors are drawn brighter so the hue shows; Y is the true luminous value.
Air
Fused silica substrate
A single cavity with no blocking stack. Outside the mirrors' stop band it passes light again, and that leak sets most of the transmitted color.
Indices: fused silica, Malitson (1965); MgF₂, Dodge (1984); TiO₂, DeVore (1951), bulk rutile, so evaporated films run lower; Ta₂O₅, Rodríguez-de Marcos et al. (2016); N-BK7, the SCHOTT catalog.
At 13.5 nm the same calculation matches the Mo/Si mirror model on the EUV and DUV optics page to nine decimal places.
Live controls need JavaScript
Illustrative sample · coating designs · coated face only, the back face of the substrate is left out
From your measured data. I work from your test data and drawings.
Your engineers own the numbers. I don’t generate, certify or guarantee specifications; your engineers sign off every value.
Gaps go to you as a list. A missing condition or a unit that doesn’t match is flagged for your engineers, not filled in.
Product-page content. I write the copy, tables and FAQ; your web person builds the page from my notes.
Yes. Send the current PDF and the data behind its curves.
To redraw curves, yes: the data behind each curve, under NDA if you like. For a copy-only refresh, the current datasheet is enough.
Yes. Or I set up a clean template you can reuse for the rest of the family.
No. I make the conditions and limits clear; your engineers decide every value.
Launching a new part? The Product Launch Package covers the datasheet refresh, the product page, a technical article, three posts and the launch email.
See the Launch PackageThe free review compares your technical content with two competitors and recommends a first project with its price.